Sistemi Dry Sorbent Injection per abbattimento fumi acidi

Dry Sorbent Injection (DSI) systems for acid gas abatement: how they work and where they are applied

Home › Blog › Dry Sorbent Injection (DSI) systems for acid gas abatement: how they work and where they are applied
Published on 18 November 2026 | Categories: Blog

Dry Sorbent Injection (DSI) systems are industrial flue gas treatment technologies designed to neutralise acid gases, such as sulphur dioxide (SO₂), hydrogen chloride (HCl) and hydrogen fluoride (HF), through the direct injection of dry sorbents, typically sodium bicarbonate and hydrated lime.
Once injected, the sorbents react chemically with the pollutants to form solid salts, which are subsequently captured and removed by downstream filtration systems, usually baghouse filters. In this article, we explore how this technology works and examine its key industrial applications.

Application contexts for DSI systems

Dry sorbent injection systems are primarily deployed in energy-intensive industrial processes characterised by hot particulate emissions and corrosive acid gases. Key sectors include:

  • waste-to-energy (WtE) plants and waste incinerators that generate peak concentrations of HCl and SO₂;
  • ceramic manufacturing and firing, which releases fluorides, chlorides, SO₂, and particulate matter;
  • cement production, which generates complex flue gases;
  • biomass or fossil fuel combustion, producing flue gases with variable pollutant loads.

In all these applications, alongside the acidic nature of the pollutants, system design must account for the high operating temperatures of the generated flue gases.

How do sorbent dosing systems work?

The operation of DSI systems can be broken down into four key stages: sorbent injection, mixing with pollutants, in-duct reaction and filter cake reaction.
To protect the plant, the technology is integrated upstream of the baghouse filters, shielding metallic structures and filter media from corrosive compounds. This configuration also allows reagents to build up on the filter bags, forming a dust cake where the chemical abatement of residual pollutant molecules takes place. Let us examine each stage of the process in detail.

Sorbent injection

The sorbents used in this process are stored in a silo and conveyed into the ductwork or reactor via a pneumatic conveying system. The required sorbent feed rate (measured in kg/h) is determined by:

  • assessing the concentration of acid pollutants to be removed;
  • calculating the stoichiometric (theoretical) amount of reagent required to neutralise the acid;
  • adjusting these calculations to real-world operating conditions, including flue gas temperature, target abatement efficiency and flow rate fluctuations.

To ensure an effective chemical reaction, the sorbents must be evenly distributed across the entire duct cross-section and injected at a velocity sufficient to keep the material suspended in the gas stream.

Mixing reagents with pollutants

At this stage, evaluating the required contact (residence) time for the chemical reaction to occur is critical. Depending on the application, mixing takes place within one of two main configurations:

  • conveying ductwork in which the injected sorbent forms a dry cloud that mixes instantaneously with the gas stream. This layout may require long, straight duct runs to ensure adequate residence time;
  • dedicated reactor (DSI reactor) engineered with specific internal geometry to optimise turbulence and gas-solid contact time, thereby reducing the overall footprint of the installation.

Chemical reaction within the duct or reactor

The reagents used in this process consist of fine alkaline powder granules. When they collide with acid gas molecules, a chemical reaction occurs in which the acid and base bond permanently. This reaction produces solid salts, the composition of which depends on the reagent used:

  • with sodium bicarbonate, the acid gas is primarily converted into sodium chloride, sodium sulphate and other minor salts;
  • with hydrated lime, the acid gas is primarily converted into calcium chloride, gypsum (calcium sulphate) and other minor salts.

Reaction in the filter cake

The solid salts generated by the reaction are carried into the baghouse filter, where they are intercepted and retained. Unreacted sorbent also deposits on the surface of the filter bags, forming a porous layer known as a “filter cake” that the flue gases must pass through before reaching the exhaust stack.
The filter cake is a vital component of the system, as it captures solid salts and scrubs any remaining trace pollutants. Maintaining high operational efficiency requires controlled cake management to achieve the optimal balance between alkaline capacity and differential pressure (delta-P). This involves monitoring:

  • the amount of active reagent present in the cake that must be sufficient to effectively neutralise incoming acid gases (alkaline capacity);
  • that the cake does not put up excessive resistance to the passage of air. The delta-P measures the pressure drop between the clean and dirty sides of the filter bags. A cake that is too thick increases pressure drop and causes premature bag blinding, whereas a cake that is too thin provides insufficient contact surface area, risking acid gas slip through the stack.

Comparison of sorbents used in DSI flue gas treatment

The two most widely used sorbents in Dry Sorbent Injection (DSI) systems are:

  • hydrated lime that traditionally operates within an optimal temperature window of 120°C to 160°C. It requires adequate flue gas moisture to maximise removal efficiency. Below 120°C, provided sufficient humidity is present, it can effectively abate HCl and HF;
  • sodium bicarbonate that, upon injection into the hot gas stream, it undergoes thermal activation releasing carbon dioxide and water to transform into sodium carbonate. This creates a highly porous structure with an exceptionally high specific surface area, which is ideal for capturing and neutralising acid gases. Its optimal temperature window ranges from 120–160°C up to approximately 150–220°C (the upper limit being dictated by the thermal resistance of downstream filter media). Flue gas moisture is far less critical than temperature for this reagent.

Selecting the most suitable sorbent is never a one-size-fits-all decision. It requires a thorough analysis of flue gas temperature and moisture levels, pollutant concentrations, and the acid dew point, a critical parameter for preventing condensation and corrosion within the plant.
The table below outlines the indicative abatement performance of both sorbents across major acid gases:

PollutantHydrated lime Ca(OH)₂ abatement efficiencySodium bicarbonate NaHCO₃ abatement efficiencyTechnical notes
Hydrogen fluoride (HF)92 – 95%>95%Lime has a higher chemical affinity for fluorine, capturing it faster and more selectively.
Hydrogen chloride (HCl)Up to 85%89-99%Sodium bicarbonate keeps the system stable and reliable even during sudden, high pollutant peaks.
Sulphur dioxide (SO₂)10-80%66-99%Sodium bicarbonate delivers significantly higher removal efficiency.
Sulphur trioxide (SO₃) / Sulphuric acid (H₂SO₄)Up to 90%98-99%Both sorbents are effective, though sodium bicarbonate is more commonly used.

DO YOU NEED SUPPORT AND INFORMATION?

Our team is here to help. Please feel free to contact us for further information or assistance regarding our products and services.

Moisture and temperature in Dry Sorbent Injection systems

In Dry Sorbent Injection (DSI) systems, controlling flue gas temperature and moisture levels is critical to maximising abatement efficiency and protecting the entire plant. Operating conditions must remain within a strictly controlled thermal and hygrometric window to prevent equipment damage and adverse operational issues.

The risks of excessively high temperatures

When flue gas temperatures exceed critical design thresholds, the system faces severe operational and structural challenges:

  • risk of damage to the filter media;
  • reduction of the effectiveness of acid gas abatement;
  • formation of hot spots that degrade the mechanical components of the plant.

To mitigate these risks, protective measures such as thermal insulation (lagging) and emergency bypass systems must be integrated into the plant design.

The risks of low temperatures and high moisture

Dropping below the flue gas dew point compromises the mechanical integrity and performance of the filtration unit:

  • excess moisture causes dust to cake and harden on the bags, severely restricting airflow;
  • damp salt deposits create an aggressive environment that corrodes steel surfaces;
  • accumulated particulate matter turns into solid lumps or sludge inside the hoppers, causing blockages during discharge;
  • moisture leads to the formation of highly corrosive acidic or saline condensate.

The benefits of a controlled operating window

Maintaining dew point and temperature parameters within the ideal operating range ensures a balanced, reliable process:

  • the reagent remains fully active and operates at maximum chemical efficiency;
  • keeping temperatures safely above the dew point prevents the formation of corrosive liquids;
  • the dust layer on the bags retains the right permeability, ensuring a stable differential pressure (delta-P) and effortless dust release during reverse-pulse cleaning cycles.

Key advantages of DSI systems for flue gas treatment

Sorbent dosing systems offer a cost-effective solution that ensures compliance with emission limits while resolving issues caused by acid pollutants. The core benefits of this technology include:

  • low operating costs thanks to the absence of liquid reagents and water consumption;
  • high operational flexibility to adapt rapidly to fluctuating pollutant loads and process variations;
  • recovery and reuse of unreacted reagents, driving down consumable costs;
  • easily retrofitted into existing flue gas treatment lines;
  • compact footprint.

DSI systems: final considerations

Dry Sorbent Injection (DSI) systems stand out as one of the most versatile and cost-effective technologies for meeting strict environmental emission limits (such as those set out in Italian Legislative Decree 152/06, the Environmental Consolidation Act, and equivalent European standards). However, system effectiveness does not rely solely on the choice of reagents; it requires bespoke engineering that accounts for the physical variables of the specific plant.
This is where Tecnosida excels. Since 1979, we have been engineering and manufacturing tailor-made air pollution control systems designed around real-world industrial demands.

On-site technical assessment

Whether you need to audit the efficiency of an existing system, prevent operational bottlenecks or specify a new DSI installation, our engineering team is at your disposal. We provide targeted on-site inspections to analyse your exhaust gas streams and configure the ideal abatement technology for your facility. Contact Tecnosida’s specialists today for a dedicated technical consultation.